Simulated Wind Tests for Glasbausteine / Blokup Glass Modular Wall Conducted by Queensland University of Technology

Test Program Objectives

The testing enabled the following:

The tests were restricted to non-loadbearing simulated lateral static wind tests.

Test System

The system tested:

A full system descriptor, Is contained in the CET 3892 Test Report of 13th May 1994

Test Results

Inspections prior, during and after tests Including a review o1 the test results indicated:

Test Limitations

  1.  
  2. Spans
  3. Workmanship
  4. Materials

    Product Application

    The following tabulation has been derived on the basis of the test results and their interpretation for use in buildings under:

    1. AS 4055 Wind loads for housing;
    2. Standard Building By-laws to the Old Building Act; and
    3. AS 1170.2 Wind loading code Wind Classification refers to 1 and 2 above,
      1. AS 4055 uses N1 to N6 & C1 to C4 wind classifications
      2. Qld Standard Building By-laws use W33N to W70N & W41C to W70C - these are exactly equivalent to AS 4055 except N1 (W28N) Is not considered to apply in Queensland.

        Corner applications are required if any of the panel's area is located within 600mm of the corner of the wall, otherwise the General application applies. The results only apply to planar (not curved) walls.

        Pressure coefficients for use in AS 1170.2 are shown In Tables B1 8, 82 of AS 4055.

        Permissible Design Gust Wind Speeds (expressed in metres per second) are given as the number between W and N (non-cyclonic) or C (cyclonic) in the Standard Building By-law Classification.

        Panel Size Limitations

        On the basis of the theoretical behaviour o11he planar test panel with confirmations from the observed data, the following tabulation has been derived.

        Appropriate deflection and stress limitations have also been included in the establishment of this table. Wind Classification Vs Span for Span for planner Blokup Glass Bricks

        Opening Width

        Opening Height

        Wind Classification

        Max Width
        (mm)

        Max Block
        (numbers

        Max Height
        (mm)

        Max Blocks
        (numbers)

        General

        Corners

        3281

        17

        6000

        31

        to W33N (N2)

        -

        2865

        15

        -

        -

        -

        to W33N (N2)

        2702

        14

        -

        -

        W41N (N3)

        -

        2509

        13

        -

        -

        -

        W41N (N3)

        2509

        13

        -

        -

        W41C (c1)

        -

        2123

        11

        -

        -

        -

        W41C (C1)

        2509

        13

        -

        -

        W50N (N4)

        -

        2123

        11

        -

        -

        -

        W50N (N4)

        2123

        11

        -

        -

        W50C (C2)

        -

        1930

        10

        -

        -

        -

        W50C (C2)

        2123

        11

        -

        -

        W60N (N5)

        -

        1737

        9

        -

        -

        -

        W60C (N5)

        1737

        9

        -

        -

        W60C (NC3)

        -

        1158

        6

        -

        -

        -

        W60C (C3)

        1544

        8

        -

        -

        W70N (N6)

        -

        1158

        5

        -

        -

        -

        W70N (N6)

        1158

        6

        -

        -

        W70C (C4)

        -

        965

        5

        -

        -

        -

        W70C (C4)

        In defining the structural adequacy of various types of building products for wind rating purposes, the objectives of the test program have been satisfied.

        Phone : +49 6128 970-817
        Fax : +49 6128 970-818
        Postal Adress : Neuhofer Strasse 7,
        D - 65527 Niedernhausen 2
        EMail : info@Niebergall.de
        Marketing marketing@Niebergall.de
        Sales

        sales@Niebergall.de

        Service service@Niebergall.de


        This page has been created by MTK 2000 , Updated: 07.10.2008

         