The testing enabled the following:
The tests were restricted to non-loadbearing simulated lateral static wind tests.
The system tested:
A full system descriptor, Is contained in the CET 3892 Test Report of 13th May 1994
Inspections prior, during and after tests Including a review o1 the test results indicated:
The following tabulation has been derived on the basis of the test results and their interpretation for use in buildings under:
Corner applications are required if any of the panel's area is located within 600mm of the corner of the wall, otherwise the General application applies. The results only apply to planar (not curved) walls.
Pressure coefficients for use in AS 1170.2 are shown In Tables B1 8, 82 of AS 4055.
Permissible Design Gust Wind Speeds (expressed in metres per second) are given as the number between W and N (non-cyclonic) or C (cyclonic) in the Standard Building By-law Classification.
On the basis of the theoretical behaviour o11he planar test panel with confirmations from the observed data, the following tabulation has been derived.
Appropriate deflection and stress limitations have also been included in the establishment of this table. Wind Classification Vs Span for Span for planner Blokup Glass Bricks
Opening Width |
Opening Height |
Wind Classification |
|||
Max Width |
Max Block |
Max Height |
Max Blocks |
General |
Corners |
3281 |
17 |
6000 |
31 |
to W33N (N2) |
- |
2865 |
15 |
- |
- |
- |
to W33N (N2) |
2702 |
14 |
- |
- |
W41N (N3) |
- |
2509 |
13 |
- |
- |
- |
W41N (N3) |
2509 |
13 |
- |
- |
W41C (c1) |
- |
2123 |
11 |
- |
- |
- |
W41C (C1) |
2509 |
13 |
- |
- |
W50N (N4) |
- |
2123 |
11 |
- |
- |
- |
W50N (N4) |
2123 |
11 |
- |
- |
W50C (C2) |
- |
1930 |
10 |
- |
- |
- |
W50C (C2) |
2123 |
11 |
- |
- |
W60N (N5) |
- |
1737 |
9 |
- |
- |
- |
W60C (N5) |
1737 |
9 |
- |
- |
W60C (NC3) |
- |
1158 |
6 |
- |
- |
- |
W60C (C3) |
1544 |
8 |
- |
- |
W70N (N6) |
- |
1158 |
5 |
- |
- |
- |
W70N (N6) |
1158 |
6 |
- |
- |
W70C (C4) |
- |
965 |
5 |
- |
- |
- |
W70C (C4) |
In defining the structural adequacy of various types of building products for wind rating purposes, the objectives of the test program have been satisfied.